The Microduct Fisher has a low profile pulling eye permanently mounted on rod to move
easily in fiber microducts as small as 6 mm, where traditional fish tapes are too large.
• DO NOT USE ON LIVE CIRCUITS. DISCONNECT POWER. Metal tip on rod.
• Wear safety glasses and gloves.
• Keep rod inside reel when not in use. Out-of-control rod can harm personnel or property.
• Keep rod clean. Some contaminants (including water) can conduct electricity.
• Keep secure footing. Protect yourself from falling should pulling eye move suddenly or
separate from rod.
• Check for rod damage prior to use. Cracks, gouges, nicks, or white stress marks on jacket
or sharp bends will weaken rod. Injury could result if rod breaks while being pulled.
• Do not use slip joint pliers, locking pliers or powered pulling equipment on rod.
• Do not force a pull that is stuck. Remove wires and check for kinks or obstructions.
• Avoid pulling rod over sharp edges.
• Do not bend rod beyond 1.5" radius.
Read manufacturer's instructions before using adhesive. In case of eye contact, flush with
water and seek medical attention If skin contact occurs, apply solvent (such as nail polish
remover) to area and gently remove adhesive. Wash solvent off with water. Solvents should
not be used in case of contact with eyes or open wounds.
Always wear safety goggles (ANSI Std. Z87.1) and gloves when working with adhesive and/or
unprotected fiberglass rod. See adhesive product label for SDS.
Jameson products carry a warranty against any defect in material and workmanship for a pe-
riod of one year from date of shipment unless failure is due to misuse or improper application.
Jameson shall in no event be responsible or liable for modifications, alterations, misapplications
or repairs made to its products by purchaser or others. This warranty is limited to repair or re-
placement of the product and does not include reimbursement for shipping or other expenses
incurred. Jameson disclaims any other express or implied warranty.
OPERATION AND SAFETY MANUAL
Stand Model
WARNING - ADHESIVE
Warranty
www.SpartacoGroup.com
Clover, SC
Handheld Canister
MDR_MO4

Publicidad

loading

Resumen de contenidos para SPARTACO JAMESON Microduct Fisher

  • Página 1 OPERATION AND SAFETY MANUAL Handheld Reel Model Stand Model Handheld Canister The Microduct Fisher has a low profile pulling eye permanently mounted on rod to move easily in fiber microducts as small as 6 mm, where traditional fish tapes are too large. •...
  • Página 2 Fishing Conduit With Microduct Fisher 1. Disconnect power 2. Identify both ends of conduit to be fished. Ensure switch gear or other compo- nents in area of vault or box will not be damaged by tape entering vault or box. 3.
  • Página 3 Manual de operación y seguridad Modelo de bobina portátil Modelo de soporte Canastillo portátil Microduct Fisher tiene un enganche de perfil bajo montado de modo permanente en una varilla para moverse fácilmente en microductos de fibra de tan solo 6 mm, donde el alambre guía tradicional es muy grande.
  • Página 4 Conducto de unión con Microduct Fisher 1. Desconecte la corriente 2. Identifique ambos cabos del conducto que desea buscar. Asegúrese de que los interruptores y demás componentes en la bóveda o caja no sufrirán daños cuando la cinta ingrese. 3. Si el conducto tiene un cable, use la punta flexible de la vara para empujarlo. 4.

Este manual también es adecuado para:

Jameson microduct fisher ii handheldJameson microduct fisher ii stand8-18-165mdr10-18-350mdr10-18-350mdrs