INSTALLING THE RUP-503 ON THE TRIPOD
Locking hole
Locking pin
1. Open the grip.
4. Close the grip. Lock the grip using the lever.
Grease the lever's thread with small amount
of constant lubricant before installation. The
winch shall not slide on the profile.
7. Put the rope on the pulley. Ensure that the
cable is correctly placed on the roller of the
pulley.
2. Put the 27960 on the triopd's leg. The grip
of the 27960 must be fastened on the locking
hole situated on the bottom wall of the leg's
profile.
fune
viti
5. Guide the rope behind 2 bolts located abo-
ve the reel.
8. Attach the energy absorber to the cable
using the connector suppllied with the
absorber.
3. Fit the locking pin into the hole in the tri-
pod's leg.
6. Anchor the pulley to the central anchor
eye bolt of the tripod. Both walls of the pulley
should be linked together using the connector
supplied with the pulley. Ensure the connector
is closed and locked.
9. Connect absorber's connector to the at-
tachment element of a harness. Use "A" fron-
tal or dorsal attachment point in full body har-
ness (EN 361) or rescue arttachment point in
rescue harness (EN 1497) or rescue loops
(EN 1498).