1 TECHNICAL SPECIFICATIONS

Power supply
voltage
Contacts max. Load
Nr. of microswitches
Type of Contacts
NC/NO - NC/NO
IP Class
Lock
41,5 - 45 mm
Release Travel
Installation
IMPORTANT: Do not remove the safety plug
shown in Fig.11, before this is expressly
indicated in the installation procedure.
2 INSTALLATION
To install the XK 21 device, observe the following steps:
1.
Position the device near the automated system to be
piloted/released. Take into consideration the overall
dimensions shown in Fig. 1;
2.
Fig.3 shows the rear of the device, indicating the slot for
routing the electric cables ( ref.
of the traction cable for manual release ( ref.
3.
Use XK 21 to mark the on-wall references of the holes,
as shown in Fig.4 ref.
IMPORTANT: Make sure that the hole for
routing the electric cables and the release
cable, has a diameter of not less than 20 mm
and is positioned as shown in Fig. 4 ref.
4.
Secure the device on a wall;
5.
Connect the electric cables coming from the
automated system to the relevant terminal-boards
of the microswitches (Fig.5) according to the type of
command:
NO
= Normally OPEN
NC
= Normally CLOSED
C
= COMMON
ref.
= EARTH cable fitting
IMPORTANT: It's forbidden to use the XK21 as
electric shunt box!
6.
Fit the release cable, without a sheath, inside the
hole as shown in Fig. 6 ref.
tensioning device ( ref.
7.
Before you tighten the release cable on the tensioning
device, take the device to the travel limit, as shown in
Fig. 6 ref.
, turning the head of the adjusting screw
with a hexagon wrench;
Make sure that the door of the XK 21 device
is kept open by the red Locking Lever
ref.
in Fig.2, before tightening the cable
on the tensioning device.
L
H
24 Vdc
115 - 230 V~
24 V~
(+6% -10%)
100 mA
15 A
2
2
NC/NO - NC/NO
55
55
Standard
Standard
DIN 18252
DIN 18252
41,5 - 45 mm
25 mm
25 mm
On-wall
On-wall
) and the housing
;
, crossing also over the
);
8.
Using a pair of pincers, apply tension to the cable
WITHOUT RELEASING the connected OPERATOR, and
then tighten the release cable on the tensioning
device with the relevant screw;
9.
Turning the head of the adjustment screw with a
hexagon wrench, move the tensioning device until
you release the operator, connected as shown in
Fig. 7 ref.
;
10.
Cut excess cable at the exit of the tensioning
device;
11.
If it is not present, fit the lock, conforming to standard
DIN 18252 on the front of the XK 21 device as shown
in Fig. 8;
To facilitate fitting the lock, push down
the top ends of the levers activating the
microswitches as shown in Fig. 8 ref.
12.
Fasten the lock, inserted as above, with the supplied
plate and screws ( Fig.8 );
13.
Join the front part to the part secured to the wall,
tightening the four self-forming screws as shown in
Fig. 9 ref.
;
14.
Check activation of the microswitches, turning the key
in the lock according to the diagram in Fig.10:
A
= activation of microswitch ref.
B
= activation of microswitch ref.
C
= detachment of release lever
IMPORTANT: Check if position C corresponds
to the disappearance of the piston
ref.
in Fig.9, inside the body of the
);
device.
15.
When you have checked the activation of the lock
release piston, remove the safety plug from the release
lever as shown in Fig. 11;
16.
Close the XK 21 device, first lifting the red Locking
Lever, and then the Release Lever to close the device
as shown in Fig. 12.

Declaration of Conformity

Manufacturer : FAAC S.p.A.
: Via Benini, 1 40069 Zola Predosa
Address
Declares that : Device XK 21
conforms to Low Voltage Directive
2006/95/CE
Bologna, 01 December 2007