REPLACING THE HEAD KIT (CONT.)
Step 8: Fasten the lid to the ratchet head with lid screws.
See fig. 8
Test the functionality by making sure the driver turns and
the switch can pivot in both directions.
OPERATION
1. To unlock the handle, hold the body firmly and pull the
collar downward. This will allow you to rotate the
handle clockwise or counter clockwise to your desired
torque measurement.
2. Set the desired torque by rotating the handle clockwise
or counter clockwise. For example 85 ft. lbs:
a. Rotate the handle until the vertical red line on the
major scale is lined up with 80 ft. lbs.
b. Then slowly rotate the handle clockwise and set the
minor scale to five (5).
3. Push the collar back to its locked position.
4. Install the proper socket or attachment to the square
drive end and apply to the object receiving torque.
Rotate the wrench in a clockwise steady motion until
you feel/hear a "CLICK" sound.
5. IMPORTANT: ALWAYS reset the major scale torque
measurement back to "ZERO" when you are finished
using the wrench. This will ensure the internal body
spring maintains accurate tension which prolongs the
life and accuracy of the product.
TW12TD36
Fig. 8
Minor Scale
Major Scale
6
Collar
(A) Handle
Apply Force
Rev. 06/08/16