MEMoRY MoDE

Storing Measurements
• During operation every measurement taken will be
stored sequentially (1-3) in the wrench's memory.
Example: If the wrench has taken 2 measurements,
then the first number stored (1) is going to be the most
recent measurement taken. The number (2) will be the
oldest stored measurement.
• When the number (3) is reached, the wrench will simply
roll over and delete the oldest or last (3) measurement
as a new measurement is taken.
• The storage mode cannot be modified.
• Note: Unit will not store a value that exceeds 110% of
the rated maximum torque rating.
Searching Stored Torque Measurements
1.
Press "U" & "+" key simultaneously to enter
Memory Mode.
2.
Press "+" or "-" key to access and scroll through
the recorded torque values.
3.
Press "U" key to exit Memory Mode.
TRAcK AND PEAK HolD oPERATIoN
When torque is applied, the real time torque value is
displayed. After removing the applied torque, the LCD
display will flash the peak recorded value 5 times then
the wrench will automatically reset to preset torque
value. The LED's will track the measurement as force is
applied at 90, 100, and 110% of the set torque value.
(90 is indicated by a yellow LED, 100 is indicated by a
green LED, and 110 is indicated by a red LED.)
NOTE: During the 5 flash cycle, if torque is applied to
the wrench it will hold that measurement for
approximately 1 min, and then reset to the preset
torque value.
oVERloAD
• When the force applied is over 110% of the
maximum torque rating for the wrench, the red LED
light will blink and the LCD display will flash "FULL".
• The 'FULL" indication means the wrench needs to
be reset.
• Please press the "On/Off" key for 3 seconds to
power off the wrench and reset the "FULL" indicator.
ETW38 and ETW12