Manual settings:
Used to set manually the desired projection mode when no external controller is used.
 Press the MENU button until the display shows "Manu".
 Press the ENTER button, the display shows "CoLo"
 Press the ENTER button if you want to set the color:
Use the DOWN and UP buttons to set the desired color (value from 0 to 255 according to
channel 3 of the DMX chart)
Press the ENTER button to confirm
 Use the DOWN and UP buttons to go to "UAue"
 Press the ENTER button if you want to set the rotation speed and direction:
Use the DOWN and UP buttons to set the desired rotation (value from 0 to 255 according to
channel 2 of the DMX chart)
Press the ENTER button to confirm
 Use the DOWN and UP buttons to go to "diMM"
 Press the ENTER button if you want to set the dimmer level:
Use the DOWN and UP buttons to set the desired light output level (value from 125 (low
output) to 255 (maximum output))
Press the ENTER button to confirm
 Press the MENU button for about 2 seconds if you want to exit the Menu and start running the
programmed show.
Test
 Press the MENU button until "teSt" is shown on the display.
 Press the ENTER button: the display will start blinking while the unit will run all the possible functions.
 Press the ENTER button or the MENU button to exit the TEST mode
Press the MENU button for about 2 seconds if you want to exit the Menu and go back to the normal running
mode.
Temperature:
Used to show the inner temperature of the unit.
 Press the MENU button until "teMP" is shown on the display.
 Press the ENTER button to show the temperature of the unit.
Press the MENU button for about 2 seconds if you want to exit the Menu and go back to the normal running
mode.
Fixture Hours
Used to show the number of working hours of the unit.
 Press the MENU button until "FhrS" is shown on the display.
 Press the ENTER button to show the number of working hours in the display.
Press the MENU button for about 2 seconds if you want to exit the Menu and go back to the normal running
mode.
Software version:
Used to show the software version of the unit.
 Press the MENU button until "uer" is shown on the display.
 Press the ENTER button to show the software version of the unit.
Press the MENU button for about 2 seconds if you want to exit the Menu and go back to the normal running
mode.
Reset:
Used to reset
 Press the MENU button until "rSet" is shown on the display.
 Press the ENTER button to start up the reset function.
 "UAu" will be shown on the display while the unit is doing its reset. Please wait until "UAu" is not shown
anymore on the display.
JB SYSTEMS
®
OPERATION MANUAL
5/41
LED SEAWAVE 50W
ENGLISH
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation for 1 standalone unit:
 Just insert the mains cable.
 When there is no DMX cable connected to the DMX input, the unit will start working immediately in
stand-alone mode.
 You can adapt the standalone mode to your own taste. Just make the desired settings in the main menu.
(see the previous chapter "how to set up / Main Menu / Manual Settings")
Remark: You can connect a CA-8 remote controller to the unit if you want to have more control. Refer to
"how to operate the unit" to learn how to do this.
Electrical installation for two or more units in master/slave:
 Connect several units together using good quality balanced microphone cables. The first unit of the
chain must have no DMX cable connected to its DMX input and must be set to master mode, the other
units must be set to slave mode (SL 1). See the previous chapter for more information.
 Make sure that all units are connected to the mains.
 Done!
 You can adapt the standalone mode to your own taste. Just make the desired settings in the main menu
of the MASTER unit. (see the previous chapter "how to set up / Main Menu / Manual Settings")
Remark: You can connect a CA-8 remote controller to the "Master" unit if you want to have more control.
Refer to "how to operate the unit" to learn how to do this.
Electrical installation in DMX-mode:
 The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
"daisy chain" your DMX controller and all the connected units with a balanced cable of good quality.
 Both XLR-3pin and XLR-5pin connectors are used, however XLR-3pin is more popular because these
cables are compatible with balanced audio cables.
Pin layout XLR-3pin:
Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)
Pin layout XLR-5pin:
Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+) ~ Pins4+5 not used.
JB SYSTEMS
®
OPERATION MANUAL
6/41
LED SEAWAVE 50W

Publicidad

Tabla de contenido
loading

Tabla de contenido