5.3 Functional chart
The following chart provides an overview of the
switching conditions depending on the adjusted
mode and level.
Level
Mode max.
Mode max.
Mode min.
Mode min.
Failure
any
LFV200
Switching sta-
Control
tus
lamp
transistor con-
Green
ducts
or
Switch closed
transistor
Red
blocks
or
Switch open
transistor con-
Green
ducts
or
Switch closed
transistor
Red
blocks
or
Switch open
transistor
ashes red
blocks
or
Switch open
6 Maintain
6.1 Maintenance
When used as directed in normal condition, LFV200
is maintenance-free.
7 Dismounting
7.1 Dismounting steps
Warning:
Before dismounting, be aware of dangerous
process conditions such as e.g. pressure in
the vessel, high temperatures, corrosive or
toxic products etc.
Take note of chapters "Mounting" and "Connecting
to power supply" and carry out the listed steps in
reverse order.
7.2 Disposal
The instrument consists of materials which can be
recycled by specialised recycling companies. We use
recyclable materials and have designed the electro-
nics modules to be easily separable.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive
2002/96/EG and the respective national laws (in
Germany, e. g. ElektroG). Pass the instrument
directly on to a specialised recycling company and
do not use the municipal collecting points. These
may be used only for privately used products
according to the WEEE directive.
Correct disposal avoids negative effects to persons
and environment and ensures recycling of useful raw
materials.
Materials: see chapter "Technical data"
If you cannot dispose of the instrument properly,
please contact us about disposal methods or return.
Maintain