Select pump: Press"←" or "→" to select the pump to be setted. Pumps 5 – 8 can only be setted if
the add-on (reefdoser add 4) is used. Select the requested pump, press „Enter" and set the required
number of doses per day („Time per Day"). A maximum of 24 doses are possible.
Dosage (Time Per Day): The required dosages per day can be set by the arrows "↑" and "↓" from
1 – 24. By pressing "Enter", you can reach the interval setting. The selected pump is displayed by
„n" in Pn.
Day's interval: 0 means no interval, it is dosed daily. The largest interval is 30 and is adjusted with
the arrow keys "↑" and "↓". Press „Enter" to set the quantity to be dispensed.
Dosing volume: Amount of liquid to be added per dose. Press the "←" or "→" buttons to select the
desired number and change the value by pressing "↑" or "↓". After pressing the " Enter" button, the
required dosing time can be set. This is repeated for all doses of the respective pump.
Dosing time: Press "←" or "→" to select hours and minutes, select the required number by pressing
"↑" or "↓". By pressing the "Enter" key, you will have access to additional doses, if provided under
"Time Per Day". Press "Enter" to save the data. By the "ESC" key, you return to the main menu.
6. Safety instructions
5. This product is for indoor use only. Keep away from humidity, water and salt!
6. Never fill in corrosive or crystallizing liquid.
7. The hose should be filled with liquid before use by calibrating and the flow rate has to be set
correctly for each pump to ensure the dosing accuracy during operation.
8. The pump must not be greased in any way!
7. Changing the pump head
Beforehand, please pull the plug so that no dosage takes place during the change.
The pump head including wheels and hose is available as a spare part. To change the pump head,
the two side clips must be compressed in order to separate the head from the screwed on white
base. Maybe, you have to use a small screwdriver between the base plate and bottom plate of the
pump head and lift the head slightly. When fitting the new head, make sure that the axle is placed
exactly between the three wheels. It must be centered in front, visible in the opening.
8. Technical data power plug
Input:
100 - 240 V AC / 50 - 60 Hz
Output:
12 V DC 2.0 A
9. Warranty
Should any defect in materials or workmanship be found within twelve months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid. Proof
of Purchase is required by presentation of the original invoice or receipt indicating the dealer's name,
the model number and date of purchase, or a Guarantee Card if appropriate. This warranty may not
apply if any model or production number has been altered, deleted or removed, unauthorised persons
or organisations have executed repairs, modifications or alterations, or damage is caused by
accident, misuse or neglect. We regret we are unable to accept any liability for any consequential
loss. Please note that the product is not defective under the terms of this Warranty where the
product, or any of its component parts, was not originally designed and / or manufactured for the
market in which it is used. These statements do not affect your statutory rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
7
- Technical changes reserved - 12/2014