Fuß-/ Stativmontage
Instalación de pie/ soporte
Montage sur pied/ sur socle
Foot/ support installation
47,5
60
1
2
3
DC:
-
1+
2+
3+
AC:
N
1L
2L
3L 4L
1 2
Maße in mm/ Dimensiones en mm/
Dimensions en mm/ Dimensions in mm
085501382c
Rohrmontage
Instalación en tuberías
Montage sur tige
Pipe installation
Ader-Nummern:
Números de los
conductores:
No. des fils conducteurs:
4
5
Number of conductors:
1 = 1
4+
5+
5L
2 = 2
3
4
5
3 = 3
4 = 4
5 = 5
6 = –/N
Maße in mm/ Dimensiones en mm/
Dimensions en mm/ Dimensions in mm
Installation
Do not install indication lamp
in areas where there is hazard
of explosion!
Warning: Not to be used as
an indoor visual evacuation
signal or for the hearing im-
paired.
•
•
Installation of electrical sys-
tem must be executed by
specialists only!
Switch infeed line poten-
tial-free!
Nominal voltage of indication
lamp must correspond to sup-
ply voltage!
Protect indication lamp exter-
nally against overload cur-
rent.
When making installation,
route field wiring away from
sharp projections, corners and
internal components.
24V DC:
Protective low voltage
(VDE 0100-410), safety
transformer (EN 60742), or
converter (EN 61046) respec-
tively required for connection.
5
Danger!
Install indication lamp only
in upright position (illumi-
nated segments show to
the top).
Operate the indication
lamp only at tempera-
tures between -35°C and
+45 °C.
Danger!
Electric Current!