EN.qxd
05/05/05
7:23
en
Eliminating minor faults yourself
Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information. Customer service will charge you for advice, even if the appliance is still
under guarantee!
Fault
Displays do not
illuminate.
The interior light
does not function;
the refrigerating unit
is running.
The floor of the
refrigerator
compartment is wet.
24
Page 24
Possible cause
Power failure; the fuse has been
switched off; the mains plug
has not been inserted properly.
The bulb is defective.
The light switch is sticking
(Fig. W/1).
The condensation drainage
pipe is blocked (Fig. O/B).
Remedial action
Check whether the power is on, the fuse must
be switched on.
Change the bulb (Fig. ! 0 )
1. Pull out the mains plug or switch off the fuse.
2. -The bulb has burnt out. Pull plug out of upply
socket. Remove screen (Figure ! 0 ) then
remove bulb and exchange for a new one,
maximum 15W, 220-240 V, E 14 base.
3. -The temperature selector (figure ! 0 /3) is on
setting "O".
Check whether it can be moved.
Clean the condensation channel and outlet
(Fig. O/B).