EQUATION EQ3-9K Manual De Instalación página 127

Ocultar thumbs Ver también para EQ3-9K:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15
Installation Procedure - Outdoor unit
1 - Accessories
"Edging" for protection of electrical wires from an opening edge.
2 - Selection of the place of installation
Select the place of installation satisfying the following conditions and, at the same time, obtain a consent from the client or user.
• Place where air circulates.
• Place free from heat radiation from other heat sources.
• Place where drain water may be discharged
• Place where noise and hot air may not disturb the neighborhood.
• Place where there is not heavy snowfall in the winter time.
• Place where obstacles do not exist near the air inlet and air outlet
• Place where the air outlet may not be exposed to a strong wind.
• Place surrounded at four sides are not suitable for installation. A 1m or more of overhead space is needed for the unit.
• Avoid mounting guide-louvers to the place where short-circuit is a possibility
• When installing several units, secure sufficient suction space to avoid short circuiting.
Open space requirement around the unit
Air inlet
Air inlet
Air
outlet
3 - lnstallation of outdoor unit
Fix the unit on the foundation in a proper way according to the condi-
tion of the installation place, referring to the following information:
• Give enough room for the concrete foundation to fix by anchor bolts.
• Place the concrete foundation deep enough.
• Install the unit so that the angle of inclination must be less than 3
degrees.
• Forbidden to place the unit on the ground directly. Please confirm
there is enough room near the drainage hole on bottom plate, which
will ensure the water be drained smoothly.
4 - Installation dimension (Unit : mm)
Distance
L1
L2
L3
Note :
Servicing space
• Fix the parts with screws.
• Don't intake the strong wind directly to
the outlet air- flow hole.
• A one meter distance should be kept from the unit top
• Don't block the surroundings of the unit with sundries.
• lf the outdoor unit is installed in a place that is exposed to the
wind, install the unit so that the outlet grid is NOT pointing in the
direction of the wind.
Cushion
rubber
Power Wiring Terminal
Power Wiring Distribution Hole
Model
S-AC-7-OUT
EQ3-9K
S-AC-8-OUT
EQ3-12K
S-AC-9-OUT
EQ3-18K
S-AC-10-OUT
EQ3-24K
S-AC-11-OUT
EQ3-9+12K
Case 1
Case 2
open
300 mm
500 mm
300 mm
300 mm
open
150 mm
open
150 mm
Anchor bolt
W
D
H
L1
780
245
540
500
800
280
550
510
800
280
550
510
890
353
697
628
800
280
550
510
FR
ES
PT
IT
EL
Case 3
PL
Yes
RU
No
KZ
UA
RO
Unit
Concrete
EN
foundation
L2
L3
140
256
130/160
313
130/160
313
130
355.5
127
130/160
313

Publicidad

Tabla de contenido
loading

Tabla de contenido