PROBLEM
POSSIBLE CAUSE
Polesaw fails to
The poles are not assembled
switch
correctly.
No electrical contact between the
polesaw and battery.
The battery pack is depleted.
The lock-off lever and trigger are not
depressed simultaneously.
The battery and power tool is too hot
or too cold.
Bar and chain
No oil in the oil tank.
running hot and
smoking.
The discharge port is blocked by
debris.
Inlet opening in inner oil tank is
blocked by debris.
The sprocket is stuck and clogged
with debris.
The chain and
Chain tension for overtightened or
bar running too
loose condition.
hot and can not
Dull chain.
cutting.
Chain on backwards.
Motor running, but
Motor stops after about 3 seconds.
cutting abnormal
When using the polesaw under load,
it stops.
Battery is not charged.
Lack of bar and chain lubricant can
cause increased friction. Chain
needs to be properly maintained.
Incorrect battery storage
temperature.
English (Original instructions)
SOLUTION
Reassemble the poles according to the instructions.
To secure the battery, make sure the latches on the
battery compartment snap into place.
Charge the battery pack.
Press down the lock-off lever and hold it, then
depress the trigger to turn on the pole saw.
Refer to the battery and charger maintenance part in
the manual.
Refer to the manual to remove the bar and clean out
the debris.
lubricant.
lubricant.
Refer to Re-tensioning the saw chain in the manual.
Sharpen or replace the chain.
Refer to Replacing the Bar and Chain
assembly earlier in this manual.
Recharge the battery.
Release trigger. Restart the polesaw. Do not force
the polesaw. Refer to the manual for proper use.
Charge the battery. Refer to the battery
and charger manual for correct charging
procedures.
Make sure the polesaw always has bar and chain
lubricant.
Allow the battery pack to cool until the temperature
drops to room temperature.
6