Descargar Imprimir esta página

Haldex L31187 Instrucciones De Instalación

Publicidad

Enlaces rápidos

PLC SELECT
L31187
Rev. 10-10
ABS UPGRADE KIT
INSTALLATION INSTRUCTIONS
The PLC Select ABS Upgrade Kit
contains the following components:
• PLC Select Electronic Control Unit (ECU) (1 piece)
• ECU Bracket (1 piece)
• Hex Bolt ¼-20 (1 piece)
• Flat Washer (2 pieces)
• Lock Nut ¼-20 (1 piece)
• Lock Nut M8 (3 pieces)
• Cable Clamp Bracket (1 piece)
• Cable Clamp (1 piece)
• Power Cable Extension (1 piece)
• Sensor Cable Extension (2 pieces)
• Sensor Connector Clip (2 pieces)
• 5-Way ABS Power Connector Kit (1 kit)
• ABS Label (1 piece)
Step 1 - Remove Old Wire Loom
Unplug existing loom from all connections: the
Electronic Control Unit (ECU), valve solenoid, and
sensors. Also remove the Diagnostic cable from its
mounting. Discard the loom.
Step 2 - Remove Old ECU
Remove the existing ECU and bracket (as a unit) by
unscrewing the three retaining nuts securing the
ECU Bracket while holding the bolt head in place.
Discard the lock nuts and washers.
Step 3 - Install Power Cable Clamp
Install the Power Cable Clamp to the Power Cable
Bracket by snapping the tab of the Clamp into the
small hole on the Bracket as shown.

Publicidad

loading

Resumen de contenidos para Haldex L31187

  • Página 1 PLC SELECT L31187 Rev. 10-10 ABS UPGRADE KIT INSTALLATION INSTRUCTIONS The PLC Select ABS Upgrade Kit contains the following components: • PLC Select Electronic Control Unit (ECU) (1 piece) • ECU Bracket (1 piece) • Hex Bolt ¼-20 (1 piece) •...
  • Página 2 PLC SELECT L31187 Rev. 10-10 ABS UPGRADE KIT INSTALLATION INSTRUCTIONS Step 4 - Install Brackets ECU Bracket Install the new ECU bracket and the Power Cable Bracket as shown with the supplied M8 lock nuts. Torque the lock nuts to 60-80 in.-lbs.
  • Página 3 PLC SELECT L31187 Rev. 10-10 ABS UPGRADE KIT INSTALLATION INSTRUCTIONS Step 8 - Sensor Connections Power Connect the curb side sensor to the "S1A" plug (the upper of the two sensor plugs) on the ECU. The supplied sensor extension cable may be required to (curb) reach the ECU.
  • Página 4 500 Pinebush Road, Unit #1 Cambridge, ON N1T 0A5 CANADA valve exhaust port). PH: 519-621-6722 / FX: 519-621-3924 4. The ABS light should turn on for about 3 seconds, and then turn off. www.haldex.com L31187 US Rev 10/10 5M ALP...