Device elements
1 Electrodes
2 Suction hose
3 Cable hook
4 Air outlet, working air
5 Suction head lock
6 Air inlet, motor cooling air
7 Suction head
8 Steering roller
9 Steering roller bow
10 Dirt receptacle
11 Connection bushing
12 Suction support
13 Floor nozzle
14 Suction tube
15 Rotary switch for suction hose cross
section
16 Carrying handle
17 Filter cover
18 Scale of the suction hose cross section
19 Bender
20 Automatic remote start - electric tool
21 Socket
22 Automatic filter dedusting
23 Main switch
24 Flat fold filter
25 Filter dedusting
26 Floor nozzle holder
27 Holder for crevice nozzle
28 Holder for suction pipes
29 Power cord
30 Nameplate
Symbols on the machine
M
WARNING: This unit contains hazardous
dust. Emptying and maintenance, includ-
ing the removal of the dust bag, may only
be carried out by someone who is familiar
with the unit and wearing suitable protec-
tive gear. Do not switch on the unit until the
complete filter system has been installed
and the function of the volume-flow control
has been tested.
PES
PTFE
Safety instructions
DANGER
– When the outgoing air is carried back
into the room, a sufficient ventilation
rate L in the room must be ensured. To
comply with the required limit values the
carried back volume flow must be 50%
of the fresh air volume flow (room vol-
ume V
x ventilation rate L
R
mum. Without a specific ventilation sys-
tem the following applies: L
– Only persons trained in the use of the
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.
– 2
EN
!
Flat fold filter
Order No.
6.904-367.0
Flat fold filter (PES)
Order No.
6.904-360.0
Flat fold filter (PTFE)
Order No.
6.907-455.0
Dust disposal bag
Order No.
6.596-886.0
) at maxi-
W
=1h
W
M
.
–1
7