down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connec-
tions with appropriate clamping rings or adhesive tape (Fig. 8).
b. Before fitting the chimney to the canopy make the electrical connection as described in the section
titled ELECTRICAL.
c. Each chimney stack consists of two sections. Fit the upper sections (Fig. 2a - item 7) first by expand-
ing the chimneys slightly around the bracket and secure the chimney stacks to the brackets using the M4
screws provided.
d. Check the vertical of the chimney.
e. Pull on the lower chimney item 5 and secure it temporarily unscrewing a little bit the lower self tapping
screws as illustrated in Fig 9.
IN THE RECIRCULATION MODE:
a. Fit the recirculation spigot R onto the chimney bracket using the same fixing screws.
b. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot
and secure the connections with appropriate clamping rings or adhesive tape (Fig. 6).
c. Before fitting the chimney to the canopy make the electrical connection as described in the section
titled ELECTRICAL.
d. Each chimney stack consists of two sections. Fit the upper sections (Fig. 2a - item 7) first by expand-
ing the chimneys slightly around the bracket and secure the chimney stacks to the brackets using the M4
screws provided.
e. Check the vertical of the chimney.
f. Pull on the lower chimney item 5 and secure it temporarily unscrewing a little bit the lower self tapping
screws as illustrated in Fig 9.
• FITTING THE CANOPY ONTO THE CHIMNEY
10) Place the canopy under the chimney and fix it with the 12 TH 5X16 screws provided as illustrated in
Fig. 10. Attention: 2 persons are necessary to secure this operation.
11) Screw the lower self tapping screws of the upper chimney and fit the lower chimney section item 5 by
expending slightly it onto the canopy .
12) Connect the 2 connectors, check the connectors of the motor and place the case lighting as illustrated
in Fig. 11 a&b.
13) Test the lights and the fan motor.
14) Remove the metal grease filters. Insert the charcoal filter into the base of the motor housing and
secure the filter with two securing straps A as illustrated Fig. 6.
15) Fit the metal grease filters.
4
OPERATION
A - EXTRACTION OR RECYCLING :Your cooker hood is supplied in the extraction mode. To use the cooker
hood in the recycling mode re-programme the hood as follows:
Starting in the recycling mode (the contaminated air passes into the hood through the grease filters and
the purifying activated charcoal filter and back out into the kitchen through grilles).
Press the '+' button (while the motor and lights are switched 'OFF') until the five LED lights will flash twice
to indicate confirmation that the cooker hood is in the recycling mode.