Interface Signals - Safeline VV3 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Programación

INTERFACE SIGNALS

Binary signals
Binary code is a standardized way to control outputs that are used for fl oor displays. The benefi t is that you
use less output signals to control multiple signals. I.e. there are only 3 signals needed to display 7 fl oors, 4
signals to display 15 fl oors, 5 signals to display 31 fl oors etc.
Example:
Floor
Code
0
0000
1
0001
2
0010
3
0011
4
0100
5
0101
6
0110
7
0111
GRAY CODE SIGNALS
Gray code is a slightly more rare way to control fl oor displays.
It is often used on older controllers.
Example:
Floor
Code
0
0000
1
0001
2
0011
3
0010
4
0110
5
0111
6
0101
7
0100
DECIMAL SIGNALS (ONE-FLOOR-PER-PIN)
The old way to control fl oor displays are called Decimal or one-fl oor-per-pin.
One output signal is needed for every fl oor, i.e. 8 outputs for 8 fl oors.
Example:
Floor
Code
1
10000000
2
01000000
3
00100000
4
00010000
5
00001000
6
00000100
7
00000010
8
00000001
© 2009 SafeLine and all the SafeLine products and accessories are copyrighted by law.
Floor
Code
8
1000
9
1001
10
1010
11
1011
12
1100
13
1101
14
1110
15
1111
Floor
Code
8
1100
9
1101
10
1111
11
1110
12
1010
13
1011
14
1001
15
1000
18
SPANISH V. 2.10
06.2009

Publicidad

Tabla de contenido
loading

Productos relacionados para Safeline VV3

Tabla de contenido