INSTALLATION AND MAINTENANCE INSTRUCTIONS
CZ-6
Six Zone Interface Module
SPECIFICATIONS
Normal Operating Voltage:
Stand-By Current:
Alarm Current:
Temperature Range:
Humidity:
Dimensions:
Accessories:
Wire Gauge:
Maximum IDC Wiring Resistance:
External Supply Voltage
DC Voltage:
Ripple Voltage:
Current:
IDC:
BEFORE INSTALLING
This information is included as a quick reference installation guide. Refer to
the appropriate control panel installation manual for detailed system informa-
tion. If the modules will be installed in an existing operational system, inform
the operator and local authority that the system will be temporarily out of ser-
vice. Disconnect the power to the control panel before installing the modules.
This system contains static sensitive components. Always ground yourself
with a proper wrist strap before handling any circuits so that static charges are
removed from the body. The module housing should also be grounded.
NOTICE: This manual should be left with the owner/user of this equipment.
This manual refers only to installations conforming to EN54 requirements, for
UL installations please refer to I56-1799 (former number D500-49-00).
COMPATIBLE TWO-WIRE SYSTEM SENSOR SMOKE DETECTORS FOR USE WITH CZ-6
MODEL
1451DH
2451TH
** 2100AT
2100TB
2100TD
2100TS
2300TB
2400TH
* 2W-B
* 2W-TB
DH100LP
* Class B, Style B only
** No Accessory will be supported by 2100AT
15-32 VDC
2.3 mA @ 24V
40 mA (assumes all six LEDs solid on)
0°C to 49°C
10 to 93% Non condensing
17.3 cm H x 14.7 cm W x 3.2 cm D
Suitably grounded metallic cabinet
0.8 mm² - 3.25 mm²
25 Ohms
18-28 volts power limited
0.1 volts RMS maximum
90 mA per module
Supervised and power limited
DET.
DETECTOR
DET. ID
MANUFACTURER
1151
A
SYSTEM SENSOR
1451
A
SYSTEM SENSOR
A
SYSTEM SENSOR
2151
A
SYSTEM SENSOR
2451
A
SYSTEM SENSOR
A
SYSTEM SENSOR
5451
A
SYSTEM SENSOR
1100
A
SYSTEM SENSOR
1400
A
SYSTEM SENSOR
A
SYSTEM SENSOR
2100B
A
SYSTEM SENSOR
2100D
A
SYSTEM SENSOR
2100S
A
SYSTEM SENSOR
A
SYSTEM SENSOR
A
SYSTEM SENSOR
A
SYSTEM SENSOR
2300B
A
SYSTEM SENSOR
A
SYSTEM SENSOR
2400
A
SYSTEM SENSOR
A
SYSTEM SENSOR
A
SYSTEM SENSOR
A
SYSTEM SENSOR
A
SYSTEM SENSOR
GENERAL DESCRIPTION
The CZ-6 Six Zone Interface Module is intended for use in an intelligent alarm
system. Each module provides an interface between the intelligent alarm sys-
tem and a conventional alarm system loop. A common SLC input is used
for all modules, and the initiating device loops share a common supervisory
supply and ground. Otherwise, each monitor operates independently from the
others. Each module has its own unique address.
A pair of rotary code switches is used to set the address of the first module
from 01 to 94. The remaining modules are automatically assigned to the next
five higher addresses. Provisions are included for disabling a maximum of two
unused modules to release the addresses to be used elsewhere. Each module
also has panel controlled by color LED indicators. The panel can cause the
LEDs to blink, latch on, or latch off.
BASE MODEL
B110LP, B401
B401, B401B
DH400
B110LP, B401
DH400, B401B, B401
B401, B401B
B401
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1
Honeywell Products and Solutions Sàrl
Zone d'Activités La Pièce 16
CH-1180 ROLLE Switzerland
MAX DET.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
I56-2256-009
2/28/2020