Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SerVICe PrOCeDureS
Continued
5. Install new ignitor. Attach ignitor to rear
head with ignitor mounting screw.
6. Run ignitor wire from new ignitor through
notch in filler panel. Attach ignitor wire to
piezo ignitor.
7. Set gap between ignitor electrode and target
plate to 0.17" (43.18 cm) (see Figure 12).
WARNING: Make sure heater
is disconnected from propane
supply. Heater could ignite caus-
ing severe burns.
8. Test for spark. Push piezo ignitor button
and watch for spark between ignitor elec-
trode and target plate.
9. Place motor and fan guard into rear of
heater shell (see Motor, page 8, steps 9
and 10).
Figure 12 - Clearance Between Ignitor
Electrode and Target Plate
113855-01D
Ignitor Electrode
Gap
Area
www.desatech.com

SPeCIFICatIONS

30,000 BTU MODELS
• 30,000 BTU/Hr Output Rating
• Fuel: Propane Vapor
• Fuel Consumption/Hour:
0.33 gal (1.25 liter), 1.4 lb (0.63 kg)
• Supply Pressure To Regulator:
Minimum* 20 psi, Maximum Tank Pressure
or 200 psi
• Regulator Outlet Pressure: 10 PSI
• Manifold Pressure: 10.1 PSI
• Hot Air Output (CFM Approx): 100
• Motor: 3045 RPM, 1/40 HP
• Electric Input: 120 volt/60 hertz
• Amperage: 0.6
• Ignition: Manual, Piezo
• Temperature Range for Heater Operation:
0° F to 85° F** (-17° C to 29.4° C**)
35,000 BTU MODELS
• 35,000 BTU/Hr Output Rating
• Fuel: Propane Vapor
• Fuel Consumption/Hour:
0.38 gal (1.44 liter), 1.62 lb (0.74 kg)
• Supply Pressure To Regulator:
Minimum* 20 psi, Maximum Tank Pressure
or 200 psi
• Regulator Outlet Pressure: 10 PSI
• Manifold Pressure: 10 PSI
• Hot Air Output (CFM Approx): 100
• Motor: 3045 RPM, 1/40 HP
• Electric Input: 120 volt/60 hertz
• Amperage: 0.6
• Ignition: Manual, Piezo
• Temperature Range for Heater Operation:
0° F to 85° F** (-17° C to 29.4° C**)
40,000 BTU MODELS
• 40,000 BTU/Hr Output Rating
• Fuel: Propane Vapor
• Fuel Consumption/Hour:
0.44 gal (1.65 liter), 1.86 lb (0.84 kg)
• Supply Pressure To Regulator
Minimum* 20 psi, Maximum Tank Pressure
or 200 psi
• Regulator Outlet Pressure: 10 PSI
• Manifold Pressure: 10 PSI
• Hot Air Output (CFM Approx): 100
• Motor: 3045 RPM, 1/40 HP
• Electric Input: 120 volt/60 hertz
• Amperage: 0.6
• Ignition: Manual, Piezo
• Temperature Range for Heater Operation:
0° F to 85° F** (-17° C to 29.4° C)**
* For purposes of input adjustment
** When running heater in temperatures above 85° F
(29.44° C), high internal temperatures may cause thermal
limit device to shut down heater.