Temperature Compensation; Forced Defrost/Cooling/Heating - Haier QACT17A Manual De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Temperature Compensation

Set Temperature Compensation:
• With the display off, press and hold the FAN button for 5 seconds. The
display will then show 0 (default) or current compensation setting. Use
TEMP+/- buttons to adjust the compensation. Compensation can be
set in 1° increments
+/- 8°F (0.5°C increments up to +/-4°C).
• Temperature compensation changes the ambient temperature
reading. If the system is sensing the ambient temperature at 72°F
and the compensation is set to -2° then the system will use 70°F in its
operation to heat or cool.
Forced Defrost:
• Set to Heating mode, high fan, and 86°F (30°C), or highest temperature
if ECO is on. Press TEMP+ 6 times within 5 seconds. Three tones will
confirm that the unit is in forced defrost mode.
Forced Cooling:
• Set mode to Cool. Tap ON/OFF. Tap any button, except ON/OFF, to
light the display. Press and hold ON/OFF for 5 seconds. LL will display
and the control will beep twice. To exit, turn off control and turn it on
again.
Forced Heating:
• Set mode to Heat. Tap ON/OFF. Tap any button, except ON/OFF, to
light the display. Press and hold ON/OFF for 5 seconds. HH will display
and the control will beep twice. To exit, turn off control and turn it on
again.
12

Publicidad

Tabla de contenido
loading

Tabla de contenido