Pressure gauge (fig. C)
Your Inflator is equipped with a built-in pressure gauge (2)
that will automatically shut off when a predetermined air
pressure is reached. The gauge, which is located on the top
of the Inflator, will give a pressure reading in psi, bar or kPa.
In the case of vehicle tyres, it is recommended that the
pressure reading be verified by checking with a separate
tyre gauge.
Powering the unit (fig. C)
Warning! Do not operate the unit from both power sources
at the same time.
230 Vac mode
Always fully extend the 230 Vac cord before each use.
Connect the 230 Volt cord (5) to a suitable mains
supply.
12 Vdc mode
Warning! Do not operate the inflator when the car engine is
running.
Note: Make sure that your 12 Volt accessory socket is live.
On some vehicles the accessory socket may only become
live when the ignition key is in the accessory position.
Always fully extend the 12 Vdc cord before each use.
Remove the 12 Volt cord from the storage compartment
and plug the 12 Volt adaptor (4) into your vehicle's
12 Volt accessory socket.
Setting the required pressure (fig. C)
Warning! Do not leave the inflator running unattended.
It could burst tyres or other items.
Note: You must set the automatic shut-off feature before the
unit will operate.
When you connect to either an ac or dc power source the
digital display will be illuminated.
Press and hold - and + buttons at the same time to
select the required units, psi bar or kPa.
Warning! Excessive air pressure may cause a hazardous
risk of bursting or personal injury. Check the manufacturer's
maximum pressure rating for items being inflated.
Press the - or + buttons to set the pressure that you
require.
When set, the LCD will flash for 3 seconds and the
digital display will show zero.
Connect the universal valve adaptor and accessories
if required to the item to be inflated making sure that the
lever of the valve adaptor is in the down position to lock
it in place.
To turn the inflator on, press the on off switch (7) located
on the digital gauge.
6
Note: If the power source is removed all of the settings will
be lost and will need to be re-entered following the
instructions under the heading 'Setting the required
pressure'.
When the item being inflated has reached the pre-set
value the unit will automatically turn off.
Note: To turn the inflator off at any time, press the on/off
switch (7) located on the digital gauge.
Remove the valve adaptor or accessory from the
inflated item and disconnect the unit from the power
source.
Using your inflator as a pressure gauge
Make sure that the unit is powered as described in the
section 'Powering the unit'.
Connect the universal valve adaptor and accessories
if required to the item to be inflated, making sure that the
lever of the valve adaptor is in the down position to lock
it in place.
The display will now display the actual pressure value in
the item.
Maintenance
Your Black & Decker tool has been designed to operate over
a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regular cleaning.
Warning! Before performing any maintenance or cleaning
on the appliance, unplug the appliance.
From time to time wipe the appliance with a damp cloth.
Do not use any abrasive or solvent-based cleaner.
Do not immerse the appliance in water.