• If a malfunction occurs in the unit, a message accompanied by an error code will appear on the display (10).
This code stands for a more precise definition of the error (see table)
• An error can be reset by pressing the function button (2)
Display
Designation
Err 01
Unit temperature too
high
Err 02
Heating element
temperature
too high
Err 03
Temperature probe
Err 04
Err 05
Contact Leister service point
Err 06
Err 07
Err 08
26
Cause of error
Ambient temperature higher than
specified
Inlet air temperature higher than
specified
Air inlet blocked
Stainless steel filter blocked
Air outlet blocked
Incorrect nozzle installed
Air inlet blocked
Stainless steel filter blocked
Air outlet blocked
Incorrect nozzle installed
Temperature probe connection
faulty
Temperature probe defective
for 3 seconds.
Troubleshooting
Reduce ambient temperature
Reduce inlet air temperature
Check air inlet
Clean stainless steel filter
Check air outlet
Monitor nozzle
Check air inlet
Clean stainless steel filter
Check air outlet
Replace nozzle
Monitor the connection of the
temperature probe
Contact Leister service point