Walk test
Two minutes after applying power, walk test the protected area to verify
proper operation.
For installations on uneven surfaces slide the PCB inside the internal base to
the appropriate setting according to the desired height (1.0m, 1.5m, 2.2m,
2.7m) as printed on the bottom left corner of the PCB or use the standard
swivel accessory.
For reducing the detection range, slide the PCB up or tilt the swivel down.
LEDs Display
LED
State
Steady
RED
RED followed By
RED & YELLOW
YELLOW
Operational Modes:
Operational Mode
Description
Dead time (between detection alarms) is 2.5 Minutes.
Normal
Dead time (between detection alarms) is 2.5 sec.
Test (walk test)
The unit transmits a WRITE message each time both of the Tamper
Write
Switches (back and cover) are closed for at least 3 seconds.
Notes:
After power up the detector enters into test mode for a period of 20 minutes (disregarding the DIP switch Modes
Position).
Transmitter/Receiver Communication link setup
The detector must identify itself to the system's receiver by writing its coded message into the
receiver's address memory. This is accomplished by performing the following steps:
1. Set the receiver to Write Mode.
2. Remove the insulation material from the batteries and place them in the batteris holders on
the PCB on the right direction (pay attention to the "+" and "–" diagram on the PCB)
3. Send a WRITE message by pressing both of the tamper switches (back and cover) for at
least 3 seconds.
4. Verify that the detector has been identified by the receiver.
CAUTION NOTICE
Changes or modifications not expressly approved by RISCO Group may void the user's authority to
operate this equipment.
Simultaneous transmissions from two different units may cause message interference resulting in
loss of information.
The communication quality of this unit may be affected by its surrounding environment. Nearby
electrical equipment may interfere with its normal operation.
The operation of this unit must, therefore, be tested at each installation since its transmission
quality may vary as a result of operational conditions.
NOTE:
DIP-Switch 1 should be in ON position to enable LED indications (regardless during the first 20 minutes after
power up).
8
Description
Indicates ALARM
Indicates ALARM + Anti-masking
Installation Instructions
1.00M
1.50M
2.20M
2.70M
PCB