GFCI INSTRUCTIONS
STEP 1: Plug the Ground Fault Circuit
Interrupter (GFCI) into a working outlet.
STEP 2: Press ''TEST'', then press
''RESET'' to assure proper connection
to power.
Note: The actual appearance of the
GFCI may be different from this illustra-
tion.
Operation
DANGER
Danger of explosion! Do not spray flamma-
ble liquids.
DANGER
Risk of injury! Never use the appliance
without the spray lance attached. Check
and ensure proper fitting of the spray lance
prior to each use. The screw connection of
the spray lance must be finger-tight.
DANGER
Risk of injury! Hold the hand spray gun and
the spray pipe firmly with both hands.
DANGER
Risk of injury! The trigger and safety lever
may not be locked during the operation.
DANGER
Risk of injury! Contact Customer Service if
the safety lever is damaged.
ATTENTION
– Risk of damage! Never operate device
with an empty fuel tank. The fuel pump
will otherwise be destroyed. This also
applies to cold water operation.
10
– Risk of damage! Never operate the ap-
pliance without a filter in the water con-
nection.
– Risk of damage! Do not place any ob-
jects (hose, etc.) on or over the chimney.
Open/close the hood
Illustration
Unlock the hood lock using a screwdriv-
er, pivot the appliance hood forward
and unhook it.
Illustration
Hook in the appliance hood (see ar-
rows), pivot it up and lock in the hood
lock.
Opening/closing the trigger gun
To open the trigger gun: Actuate the
safety lever and trigger.
To close the hand spray gun: Release
the safety lever and trigger.
Replace the nozzle
DANGER
Risk of injury! Switch the appliance off prior
to replacing nozzle and activate hand spray
gun until device is pressureless.
Secure the trigger gun. To do so, push
the safety catch towards the front.
Replacing the nozzle.
Operating modes
Illustration
0/OFF = Off
1 Operating with cold water
2 Operating with hot water
Turning on the Appliance
Set appliance switch to desired operat-
ing mode.
The device starts briefly and turns off, as
soon as the working pressure is reached.
Release the trigger gun. To do so, push
the safety catch towards the back.
When activating the hand spray gun the de-
vice switches back on.
Note: If no water comes out of the high
pressure nozzle, vent pump.
Vent pump:
– 5
EN