5. Installation of wall-mounted mixers and thermostatic mixers
Important!
• The mixers are designed for a water pres-
sure of minimum 1 bar and maximum 5 bar.
• Maximum water temperature must not
exceed 80°C. Recommended, maximum
water temperature: 65°C
Installation of wall-mounted mixer
All mixers for wall mounting are supplied with
3/4" union nut and with rosettes and srewed
connections.
Without use of eccentric wall connections, the di-
stance between centres may vary between 150 and
153 mm.
1. Before installation, the cold-water and hot-
water pipes must be thoroughly flushed.
2. The enclosed filters (thermostatic mixer)
must be used as gaskets.
3. Connect the cold-water pipe to the right inlet
of the mixer.
4. Connect the hot-water pipe to the left inlet of
the mixer.
See also instructions for thermostatic mixer.
6. Instructions for A1 and A3
Adjustment of water temperature
6
Mounting of spout for bath tub with switch for
hand shower
Screw the union nut of the spout on to the outlet
nipple (3/4") of the mixer while turning the spout
tip slightly to the right (see fig. 1).
Turn the spout to the left against stop.
Then unscrew the union nut slightly to make it
possible to turn the spout to the left (you will feel
a slight resistance), until it is parallel with the mixer
body. Keep the spout in this position while
tightening the union nut (fig. 2).
Now, mount shower hose and shower.
Removal of aerator on A3
To remove the aerator of the A3 mixers, use
enclosed special-purpose wrench.
fig. 1
fig. 2