Similarly, a second switch enables the elimination of the anti-clipping circuit. When
the amplifier is in danger of being damaged by excessive temperature due to
inappropate installation or any other anomaly thus exceeding the safety limits,
(temperature >90ºC), the corresponding safety circuit will cause a stoppage for a few
seconds, with the Led coming alight. They will also light up in the event of any short-
circuiting occurring at the loudspeaker output.
12 - TECHNICAL FEATURES
Technical Features
Frequency response
Input impedance
Damping Factor (1KHz)
Crosstalk
Sensitivity
Signal/Noise ratio
Output power (1KHz - 0,1% THD)
Both channels 4 Ohm
One channel 4 Ohm
Bridge (Mono) 8 Ohm
Maximum power consumption
Size
Weight
All specifications and features are subject to change without prior notice NOV 2001
If you follow this instructions manual and recommendations, we are sure that this
amplifier will always perform within the predetermined parameters, ensuring its long
life and total efficiency.
13 - CERTIFICATE OF WARRANTY
The Conditions and Observations for the application of this Contract of
Warranty are for all the territories of the Spanish State.
For other countries, the specifications of each country must be
complied with, as only the Representative or National importer
themselves can be held responsible for warranty terms.
For any claim of a Legal type, only the Ordinary Courts corresponding
to the city of Terrassa (Barcelona-Spain) will be valid.
Please follow the instructions on the last page of this manual.
402
602
225
306
8 Ohm
160
190
338
475
450
610
2,5 A
3,5 A
482x416(F) mm - 2U 19" Rack
10 Kg
12 Kg
12
802
1002
30 Hz - 20 KHz (+/- 1dB)
20 Hz - 30 KHz (+/- 3dB)
20 Kohm
>350 (8 Ohm)
85 dB
1,225 V (+4 dBm) for full power
>100 dB
405
506
265
312
630
750
810
1010
5,0 A
6,0 A
12 Kg
14 Kg
1202
1802
595
885
385
550
930
1375
1190
1770
7,0 A
10 A
3U 19" Rack
15 Kg
17 Kg