DESCRIPTION AND INTENDED USE
ECO-LOGIC can only be installed on gate automation systems
with V2 control units.
m
ATTENTION: the control unit supplied by the
ECO-LOGIC must have the mode of operation ENERGY
SAVING active.
To ensure proper operation of the system, all the added
accessories must be connected to the accessory output of
the control unit and, during the stand-by, they will not be
supplied.
The system consists of an accumulator unit, a solar panel and en
external power supply.
The automation device is powered by the accumulator unit, which
is recharged during daylight hours.
The external power supply (accessory - code 172802) may be used
for recharging the batteries in the case of prolonged periods of
lack of sunlight.
NOTE: If the panel fails to provide sufficient charge to the
accumulator group, it is possible to install a second panel in
parallel to the first one.
• CAUTION: Before you connect the two panels, disconnect the
grey connector from the accumulator
• Exclusively use the panel with code 172801 provided by V2
• To connect the two panels in parallel, use a 2x1mm
• If the cable between the accumulator and the first panel is
longer than 3m, use a 2x1, 5mm
ATTENTION: the connections must be insulated inside a
waterproof container
- 9 -
cable
2
cable.
2