Cut the cables so that they protrude from the guide by about 5 mm, insert the guide in its plug and crimp
with the specially provided tool.
Make sure that the grey sheath stays inside the plug.
This type of connection will NOT guarantee double insulation.
MAXIMUM DISTANCES AND WIRE SECTIONS
Type of connection
LAN
Between gateway and local
power unit
If the local power supply is used, fi rstly connect the LAN cable to a non-POE port of the switch and then
connect to the local power supply.
(*) The maximum permissible distance is that defi ned by IEEE 802.3 for Fast Ethernet networks
(100 Mb/s) with UTP CAT5 connections, which establishes that the maximum distance between two
Ethernet devices connected to each other must be 100 m.
(#) To ensure operation of the device at maximum distances, the wire must be in Category 5e and the
section of the twisted pairs must be AWG24.
The maximum resistance of the individual wires must not exceed 10ohm/100m.
The connection between the door phone and POE switch must be ensured by a single cable
without any extra patch cords.
The cable must be up to the following standards:
- EIA/TIA 568-B.2 or EIA/TIA 568-C.2
- EN50288 3-1
- IEC 61156-5
INSTALLATION
IN ELECTRICAL PANEL ON DIN BAR (8 MODULES)
1. Insert the spacer behind the device in its special seat, ensuring that it is locked by the lever A.
12
~ 5 mm
1
8
Max. distance
100 m (*)
20 m
A
Plug
1
8
1
2
Min - max section
CAT5e (#)
1 mm
MAX 1,5 mm
2
2
DS1083-113