Technical data
Minimum flow pressure with downstream resistance
Max. operating pressure
Recommended operating pressure
Test pressure
Max. hot water temperature
Temperature scale adjustible
Safety check
Hot water connection
Cold water connection
Nominal capacity for ½" 3 bar
Nominal capacity for ¾" 3 bar
Minimum flow rate
The water temperature at the hot water inlet should be at least 2° C higher then the desired hot water temperature.
The Hansgrohe ½" thermostatic mixer, code number 1337318 can be used in conjunction with hydraulic or
thermostatically controlled combination boilers providing there is a minimum of 1,5 bar pressure.
The Hansgrohe ¾" thermostatic mixer, code number 1337418 cannot be used with combinaton boilers.
Spare parts
1
Thermoelement ½"
Thermoelement ¾"
1.1
O-ring for ½"
O-ring for ¾"
1.2
O-ring for ½" and ¾"
O-ring for ¾"
1.3
O-ring for ½"
O-ring for ¾"
2
N. R. valve for ½"
N. R. valve for ¾"
2.1
Filter for ½"
Filter for ¾"
3
Isolation valve for ½" and ¾"
4
Extension for ½" 40 mm
Extension for ¾" 40 mm
GB
92601
92631
92602
92632
92603
92604
92634
92605
92635
92606
92636
92607
92610
92640
0,5 bar
10,0 bar
1,0 - 5,0 bar
16,0 bar
80° C
20° - 80° C
38° C
LH
RH
32 l/min
44 l/min.
5 l/min.