WATER CONNECTION AND DISCHARGE
-
We recomemnd to connect the appliance to the warm water pipe in order to reduce the heating times. Install upstream
of the appliance an interceptor cock.
-
The discharge pipe must be connected to a suitable discharge according to law.
We recommend to connect the piping to avoid contractions or siphons. Water discharge has a free fall, therefore the
discharge must be lower than the piping outlet.

THERMAL POWER CONTROL

Appliance must be checked in order to test the right thermal poweR:
The thermal power is imentioned in the data plate;
First of all check whether the appliance is set up for the supplied gas, then ensure that the data on the plate correspond
to the gas to be used. For adapting to different type of gas, check that the gas correspond to te instruction manual.
Measure the pressure using a pressure gauge (the least resolution 0.1 mbar) inserted in the appropriate outlet (see picture
A, pos. 10). Remove the sealing screw and insert the tube of the pressure gauge. After measurement, replace the screw,
tighten it and check the tightness.
Liquid gas connection (G30/G31)
The connection pressure for liquid gas is 30 mbar for butane and 37 mbar for propane.
Check the data plate, measure the pressure and see whether the installed nozzle corresponds to the description of the
manufacturer.
Methane gas connection (H G20)
The connection pressure of natural gas is 20 mbar.
Check the data plate, measure the pressure and see whether the installed nozzle corresponds to the description of the
manufacturer.
CONTROL OF MAIN BURNERS PRIMARI AIR
All burners are equipped with a bracket (24) for the regulation of the primary air, which must be placed at a "h" distance
indicated in the data plate.

Specification table

Burner 14 kW
Burner injector 1/100 mm.
pilot injector
Consumption
Primary air
PROVISIONS FOR TRANSFORMATION AND INSTALLATION FOR OTHER TYPES OF
GAS
Our appliances are tested and set for liquid gas (see data plate inside).
Transformation ond adaptation to other types of gas must be carried out by a skilled technician. Nozzles for different of gases
are inside the supplied small bag and marked in hundredths of mm (see Specification table).
GB
IE
12.8 kWh/KG
12.8 kWh/KG
G30
G31
BUTANE
PROPANE
30 mbar
37 mbar
4 x 98
4 x 98
30
30
kg/h 1,09
kg/h 1,09
13
13
27
9.45 kWh/m
st.
3
G20
NATURAL GAS H
20 mbar
4 x 153
51
m
st./h 1,48
3
max