FEATURES
1) Front Mounted Thermostat: Easily accessible control
knob controls the desired temperature inside the freezer.
The proper food storage temperature is -18°C (0°F). The
thermostat engages the motor when the temperature rises
above the set temperature.
2) Defrost Drain: For easy removal of melted ice during
defrosting. It is recommended that you defrost your
freezer once or twice a year.
3) Rust Resistant Interior (not shown): Aluminum liner for
long lasting durability.
STARTING THE FREEZER
The freezer is ready to operate as received, when connected to
the power supply. After connecting to power supply, close lid
and allow freezer to operate. The unit will run from 1 to 2 hours
(possibly longer, depending on conditions) before operating
temperature is reached. It will then start and stop (cycle) at fairly
regular intervals. It is recommended that food not be placed in
the freezer until you are satisfied that it is operating (cycling)
regularly and no final adjustments are necessary.
Once your freezer is starting and stopping (cycling) regularly, it
is ready to freeze and store foods. The proper food storage tem-
perature is -18°C (0°F). Do not operate freezer at temperatures
below -19°C (-3°F), as this does not improve food preservation
and only results in longer unit (cycle) running time. It is not
advisable to freeze more than 25 kg.(50 lbs.) of food in any 24
hour period. It will take 15 or more hours of unit running time to
freeze this amount of food.
When adding fresh, unfrozen food packages, store them against
the walls. The sensing bulb of the thermostat is fastened to the
liner wall on the "insulation side" of the freezer. In view of the
value of the contents of your freezer, it is advisable to inspect
contents and check freezer operation regularly.
INSTALLATION INSTRUCTIONS
OPERATING INSTRUCTIONS
TEMPERATURE CONTROL
• Turn the temperature control knob clockwise to the furthest
(maximum) setting on the darker blue (wide) section of the
graduated control dial.
• Allow the freezer to run at this setting for 3-4 hours.
• When maximum cooling is achieved, turn back the
temperature control knob setting to the 2 o'clock position on
the graduated blue control dial. See Fig.14.
• To turn off the freezer (no cooling), rotate the control knob to
the "0"(off) position. See Fig.15.
Fig. 14