1.- INTRODUCTION
IMPORTANT! All local regulations, including
IMPORTANT! All local regulations, including
those that refer to national or European
those that refer to national or European
regulations, must be applied when installing
regulations, must be applied when installing
this device.
The way the Compact SERE 2C is installed will
have a decisive effect on safety issues and its
have a decisive effect on safety issues and its
correct operation.
It is important to install the fireplace correctly.
It is important to install the fireplace correctly.
To ensure your Compact SERE 2C
the chimney is installed correctly, it should be
the chimney is installed correctly, it should be
installed by a professional.
The Compact SERE 2C provides heat by
radiation; directly heating walls, ceilings...
radiation; directly heating walls, ceilings...
and by forced air convection, thanks to the fans
and by forced air convection, thanks to the fans
installed
NOTE: When installing any type of insulation to
NOTE: When installing any type of insulation to
safeguard the heat cover, take the following
safeguard the heat cover, take the following
obligatory recommendations into account:
recommendations into account:
The insulation must never come into
The insulation must never come into
•
contact with the device; this would prevent
contact with the device; this would prevent
the transfer of heat and the displacement
the transfer of heat and the displacement
of the hot air to the top of the hood.
of the hot air to the top of the hood.
Leave a minimum distance of 7 cm
Leave a minimum distance of 7 cm
•
between the insulation and the
between the insulation and the appliance.
1.2.- HOT AIR OUTLET OPTIONS
HOT AIR OUTLET OPTIONS
TOP GRILLE AIR FLOW
This is the STANDARD air exit. Air enters
This is the STANDARD air exit. Air enters
through the lower section, "A", and the internal
through the lower section, "A", and the internal
fan forces the hot air through the top section
fan forces the hot air through the top section
"B".
is installed will
fireplace and
provides heat by
AIR FLOW THROUGH THE HOOD
AIR FLOW THROUGH THE HOOD
This option is compatible with the one
mentioned above.
Brick hoods must include holes at the bottom
Brick hoods must include holes at the bottom
and at the top. These gaps can be covered by
and at the top. These gaps can be covered by
ornamental grilles to facilitate the flow of air.
ornamental grilles to facilitate the flow of air.
Cold air enters through the lower section, "C"
Cold air enters through the lower section, "C"
and exits through the upper section "D" (take
and exits through the upper
into account that your Compact SERE Fireplace
into account that your Compact SERE Fireplace
provides most of its heat by convection). If the
provides most of its heat by convection). If the
ventilation holes in the hood are not large
ventilation holes in the hood are not large
enough, the device may be damaged if it is
enough, the device may be damaged if it is
unable to dissipate the heat.
unable to dissipate the heat.
IMPORTANT! The minimum air intake gap
IMPORTANT! The minimum air intake gap
recommended is 200cm² of free passage
recommended is 200cm² of free passage
through the grille.
The air input grilles in the hood must be
The air input grilles in the hood must be
located in such a way that they cannot be
located in such a way that they cannot be
blocked.
For further
For further
information on the
information on the
installation of the device, please see the
installation of the device, please see the
Manual for the Professional Installer.
Manual for the Professional Installer.
9
compatible with the one
1. Chimney pipe
2. Hot air grille
3. Cold air grille
4. Forced convection outlet
correct