OUTLET HARDNESS MIX (ESCAPE)
•
If wanting outlet water (escape) a few degrees harder, act on the hardness mixer at the side of the valve, near
the OUT nipples by ¾". It is normally pre-set in factory as "closed" (0°/2° of escape), if wanting to open it and adjust the
escape, turn it anti-clockwise (maximum opening: rotation of 180°) with reference to the image Fig. 3 page 5. The mixer
is adjusted with white "notches" on the mixer circumference; for excellent adjustment, use a specific hardness test, taking
water as close as possible near the valve outlet and measuring its effective degrees.
DISINFECTION (ONLY FOR MODELS PROVIDED WITH IT)
•
Models provided with resin disinfection during the regeneration phase, will have the chlorination electrode
already coupled in rear part of valve. The chlorination will always be active in the F1 phase for its entire duration, without
any type of adjustment. Its verification and eventual replacement is recommended at least once a year.
RECOMMENDED HYDRAULIC CONNECTION DIAGRAM
H
K
L
M
B = Resin container cylinder
C = Valve for softening
D = Regenerant pick-up hose
E = Regenerant container (brine)
F = Discharge hose
G = Open siphon discharge sump
ELECTRIC CONNECTIONS:
•
Ensure the electric power supply plug, which the valve transformer is connected to, is not controlled by an
upstream main switch. For the correct function, the valve must be constantly powered.
•
For the correct and safe installation of the softener, it is essential to set-up a specific plug near the appliance so
that it is easily reachable, if required.