Charging Parameters; Troubleshooting - Furrion FSFP50MAT-BL Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Charging Parameters

Battery Type
System current
No-load loss
Solar energy input voltage
System voltage
Overvoltage protection
Equalizing charging voltage
Boost charging voltage
Floating charging voltage
Constant charge voltage
Constant charge recovery voltage
Boost charging recovery voltage
Equalizing charging duration
Boost charging duration
Operation temperature
Protection degree
NOTE: Charging parameters may vary based on availability of sunlight on the solar panels.

Troubleshooting

Symptoms
While sunlight is present, the solar
panel indicator does not light up.
The solar panel charging indicator
is flashing quickly.
The battery indicator does not
light up.
17
Sealed
GEL
17.0V
17.0V
14.6V
14.4V
14.2V
13.8V
13.8V
13.2V
13.2V
1 hour
4 hours
4 hours
-31
F to 149
o
Causes and Solutions
Check whether the solar panel is correctly connected
and contact is adequate.
Ensure that the correct battery type has been selected.
The battery may be failing to supply power. Check
whether the battery is correctly connected.
Lithium iron
Flooded
10A
10mA/12V
<55V
12V
17.0V
14.8V
14.6V
13.8V
13.2V
1 hour
4 hours
F (-35
C to 65
C)
o
o
o
IP65
phosphate
16.6V
14.6V
13.6V

Publicidad

Tabla de contenido
loading

Tabla de contenido