ST-Control - Operation
EN
Temperature difference control with automatic function check
General
The ST-Control is a temperature difference control with au-
tomatic plausibility check. Using the integrated Schuko
plug
(also called type F or CEE 7/4), the control is connected
quickly and without wiring work. It is simply plugged into
the socket.
Function
The ST-Control compares the temperature of the collector
with that of the SolvisTherm hot water storage tank. The
control switches on when a temperature difference
("Diff."), which can be adjusted, plus a temperature-depen-
dent hysteresis is exceeded. If the temperature goes be-
low the target value "Diff." is exceeded or if the storage
tank sensor reaches the storage tank maximum value
("Max."), the solar pump is switched off.
The difference ("Diff.") is the value by which the collector
must be hotter than the storage tank for the solar pump
to operate (recommendation 5 - 10 K).
The storage tank maximum value ("Max.") limits the stora-
ge tank temperature to prevent calcification, damage to
the storage tank coating, scalding, etc. (recommendation
60 - 90 °C). The solar pump switches back on when the
temperature goes below the set value minus the hyste-
resis.
Scope of delivery
• ST-Control controller
• 1 storage tank sensor (3 m cable)
• 1 plug (for connecting the collector sensor)
• Operating instructions (enclosed)
Technical data
Operating voltage
Power consumption
Rated pump current load
Fuse
Controller enclosure
Display range
Sensor (storage tank and collector) KTY 2 kΩ
Permissible ambient temperatures 0 - 45 °C
4
230 V / 50 - 60 Hz
max. 2 VA
max. 2.5 A
3 A fast-acting
IP 20
-99 – 199
See other side
N 15-M – Subject to technical changes 06.07