Installation
B. Mounting on a wood stud wall
covered with gypsum board drywall
1. Use a stud finder to locate two adjacent
studs. Find both edges of each stud to
mark down the center lines for two studs
with a pencil.
Note: Drywall covering the wall must not
exceed 16 mm (5∕8").
2. Place the wall plate paper template
against the wall to ensure the 4 holes line
up with the stud center lines. Level the
paper template and tape it in place.
3. Using a 1/4" (6mm) drill bit, drill 4 mounting
holes with the depth 3" (76mm). Then
remove the paper template.
4. Install the wall plate on wall using 4 lag
bolts(A) and washers (B).
Tighten the lag bolts securely and ensure
the wall plate level by using the built-in
bubble level on the mount.
CAUTION: Do not over-tighten the lag
bolts. Improper use could reduce the
holding power of the lag bolt.