Ice Maker Performance Mode Instructions (cont)
WARNING
Please read following installation before using, and choose correct drain mode according to
your using condition, and set your icemaker accordingly.
Performance
Mode
Unnecessary water
Direct drainage
mode
will be drained off
by the outlet water
(Recommended mode)
pipe on the back of
the unit
Drain pump mode
Unnecessary water
will force the drain
(Recommended mode)
out by the pump on
back of the unit.
INSTALLATION INSTRUCTIONS
Instructions
Suitable situation
The height of drain hole
in the room
≤100 mm (3-15/16")
The height of drain
hole in the room is
between
101 mm~1500 mm
(3-15/16"~59")
Operation instruction
Ref: Fig.A & Fig.B & Fig.C
Screw Nut and Switch
screw nut(front) (3) + seal washer(front)(4)
screw nut(back) (7) + seal washer(back) (6)
screw nut for valve seal (11)
screw nut for valve seal (12)
force water outlet switch (8)
≤
100 mm
1. Please insure the screw nut and switch are in the
≤
3-15/16"
above condition;
2. Use a certain length drain pipe,connect one side to
the direct water outlet pipe connection (13) the other
to the drain hole. Please insure the connection is tight
to avoid water leakage.
Ref: Fig.A & Fig.B & Fig.C
Screw Nut and Switch
screw nut(front) (3) + seal washer(front)(4)
screw nut(back) (7) + seal washer(back) (6)
screw nut for valve seal (11)
screw nut for valve seal (12)
force water outlet switch (8)
1. Please insure the screw nut and switch are in the
above condition;
2. Use a certain length drain pipe, connect one side to
the force water outlet pipe connector (10), the other to
the drain hole. Please insure the connection is tight to
avoid water leakage.
The lengthen of drainpipe is no more than 6000 mm
(236-4/16") in order to prevent slops return.
6
Condition
Condition
WARNING
lock
open
lock
open
OFF
lock
open
open
lock
ON