DESCRIPTION
Single-phase control panel for roll-up doors. Compatible with Vario and Secure radio transmitters.
Inputs protected by zener diode. Protection of main feed and motor with fuse 6A. LED indicator. Alternative button and
safety contact input.
INSTALLATION
Be sure mains are disconnected before proceeding with the installation.
DESCRIPTION OF TERMINALS
Power:
1. Supply 230V ac -
2. Supply 230V ac -
3. Closing motor -
4. Opening motor -
5. Common motor -
6. Power supply +12 VDC -
7. Power Supply -12 VDC
OPERATION
8. Safety contact
9. Common motor
10. P. Alt. Alternative button (N.O.)
N.C. Normally closed – N.O. Normally open
OPERATION
You can start the operation by means of a transmitter or an alternative button. The operation ends due to the following
conditions: activation of door limit switches or end of operating time. The door limit switches do not have connection with
the control panel. The operating time is programmable up to a maximum of 2 minutes and 30 seconds, considering this a
safety time.
In addition, the automatic closing time is programmable up to a maximum of 3 minutes and it adjusts the waiting time before
executing automatically the closing operation. The alternative button and the transmitter accomplish the same function.
If the door is opening, when we press the transmitter button or the alternative one, it stops, if we press it again it closes, if we
press it again it stops and if we press it one more time it closes again, and so on.
OPTIONS SELECTION
I1 Select Timer / Auto closing
ON timed automatic closing. OFF Automatic closing off.
I2 Timer programming
ON programming operation time (I1 OFF). Programming closing time (I1 ON).
OFF time programming disabled.
I3 Radio programming
ON radio programming for new transmitters enabled. OFF radio programming disabled
Vs
ANT.
PROG.
1.Sel.Timer/Auto Closing
2.Programming Timers
3.Programming Via Radio
4.Dead Man
8
9
10
6
7
Sec.
12V dc
Close
P.Alt
https://appceso.com

Technical specifications

Power supply
Engine power
Running time
Closing time programmable
Combination codes
Memory capacity
Programming codes
Setting functions
Frequency
Homologations
Sensitivity
Scope
Antenna
Operating temperature
For permanently connected equipment this device must
be incorporated in an accessible
cable system easy to disconnect.
230V ac +-10%
0.45hp
2 minutes 30 seconds
programmable 3 minutes
72 million codes
up to 31 codes
self-teaching stores
the function code
433.92 Mhzl
ETS 300-220 / ETS 300-683
Greater than -100 dBm
standart 70 m
Built-in
0ºC / 70ºC
4