6 F
F
F
OOT
REE
ALL
Fall clearance required for attaching with 6 foot (1.8m) energy absorbing
lanyards, and rigged for 310 pound (141 kg) users and a 6 foot (1.8m) fi rst user
free fall. These fall clearances are measured from the work platform to the next
obstruction below the platform.
WARNING!
The Synthetic Rope Horizontal Lifeline must be installed
to limit free fall of the fi rst user to 6 feet (1.8m) or less.
The installation height of the Synthetic Rope Horizontal
Lifeline and type of connecting subsystem attached
directly affect the fall clearance requirement.
S
(
...)
PAN
UP TO
10ft (3m)
20ft (6.1m)
30ft (9.1m)
40ft (12.2m)
50ft (15.25m)
60ft (18.3m)
70ft (21.3m)
80ft (24.4m)
90ft (27.4m)
100ft (30.5m)
Page 20
E
A
NERGY
BSORBING
O
U
NE
SER
20' 4" (6.2m)
22' 0" (6.7m)
23' 7" (7.2m)
25' 4" (7.7m)
26' 11" (8.2m)
28' 7" (8.7m)
30' 2" (9.2m)
31' 10" (9.7m)
33' 6" (10.2m)
35' 1" (10.7m)
L
ANYARDS
T
U
WO
SERS
21' 0" (6.4m)
23' 4" (7.1m)
25' 8" (7.8m)
28' 2" (8.6m)
30' 10" (9.4m)
33' 4" (10.1m)
35' 10" (10.9m)
38' 4" (11.7m)
40' 8" (12.4m)
43' 2" (13.2m)