2
Mount the unit on a nearby wall (using suitable hardware) of the warewasher. Try to keep the unit
within three feet from the final rinse line to avoid long tubing runs.
Getting Started
Check all applicable plumbing and electrical codes before proceeding with the installation. This
will help to ensure that the system is installed in safe and suitable manner. A wiring schematic of
the warewasher should be used as reference for making electrical connections, this is typically
provided by the warewasher manufacturer if one cannot be located on the machine itself.
INSTALLATION
Set Up &
permanently damage the unit. Mounting the unit on the side, on the back or on the vents
Operation
of the warewasher may cause thermal overload and damage or hinder the performance of
the unit.
Maintenance &
Accessories
2.1
Apply the panel unit system with the brackets and screws supplied:
Determine a suitable location for the system;
Troubleshooting
Using the bracket as a template, mark and drill holes for bolting the system to the wall;
Insert the anchors in the holes;
Bolt the bracket in place (flat side against the wall with holes on bottom) with the hardware
Contacting SEKO
Open the Cabinet Front, unscrewing of ¼ of a turn the upper screws.
Picture 1
TWINDOSE 20
INSTALLATION
CAUTION: Do not mount the unit in the direct path of steam. This can short circuit and
MOUNTING THE SYSTEM
provided;
Rev. 1.4
cod. 0000136325
4