24
22
ADJUSTMENT
Separate choke type of choke control is used for
FX921V and FX1000V Model Engines.
Separate Choke Type
Throttle Cable Installation, Adjustment
•
Link the throttle cable (A) to the speed control
lever (B) and loosely clamp the throttle cable outer
housing (C) with the cable clamp bolt (D).
•
Move the throttle lever to "FAST" position.
•
Pull up the outer housing (C) of the throttle cable
until the inner wire (A) has almost no slack, and
tighten the cable clamp bolt (D).
•
Move the throttle lever to "slow" position. Make
sure that the carburetor throttle valve pivot arm (I)
is moved smoothly.
Choke Cable Installation, Adjustment
•
Link the choke cable (G) to the choke valve pivot
arm (H), and loosely clamp the choke cable outer
housing (E) with the cable clamp bolt (F).
•
Move the equipment choke control to "OPEN" po-
sition. Make sure that the carburetor choke valve
(pivot arm) (H) is fully opened.
•
Pull up the outer housing (E) of the choke cable
until the inner wire (G) has almost no slack, and
tighten the cable clamp bolt (F).
ADJUSTMENT
•
Move the equipment choke control to "CHOKE"
position. Make sure that the carburetor choke
valve (pivot arm) (H) is completely closed.
•
Make sure that the choke valve turns from fully
close position to fully open position when actuating
the equipment choke control.