ENGLISH
12
could take several weeks before optimal shaving
performance is restored.
Remove the hairs.
Put the retaining plate back onto the shaving
unit.
Cause 3: shaving heads are damaged or worn.
B
Remove the retaining plate.
Remove the old shaving heads from the
shaving unit and replace them with new ones.
Damaged or worn shaving heads (cutters and
guards) must only be replaced with the original
Philishave HQ167 Cool Skin shaving heads!
Put the retaining plate back onto the shaving
unit.
3
Shaver does not work when the on/off
button is pressed:
Cause: the batteries are empty
B
Recharge the batteries.
4
Cover of the cartridge compartment
cannot be closed:
Cause 1: the cartridge has not been inserted
B
correctly.