NEW CONSTRUCTION INSTALLATION
INSTALL MOUNTING FRAME
& HOUSING
TABS
FRAMING
MEMBER
DUCT
CONNECTOR
DUCT CONNECTOR
BRACKET
1. Hold one side of the mounting frame so the tabs
touch the bottom edge of the framing member. Nail or
screw mounting frame in place. Extend the mounting
frame to the opposite framing member, and nail or
screw in place.
2. Snap the duct connector onto the duct connector
bracket. Attach the duct connector bracket to the
mounting frame using the screw provided. Position the
bottom edge of the duct connector bracket so it will
be flush with the finished surface of the ceiling and
tighten the screw.
3. Position the two movable brackets of the mounting
frame directly across from each other and insert the
housing into the mounting frame until it touches the
duct connector bracket. Secure the housing to the
mounting frame and duct connector bracket using the
(5) screws provided. Position the housing horizontally
as desired.
MOUNTING
FRAME
SCREW
OR NAIL (4)
SCREW
(provided)
TABS
HOUSING
SCREW (5)
(provided)
INSTALL DUCTWORK
4. Connect 4" round ductwork to duct connector.
Run ductwork to a roof cap or wall cap. Tape all
ductwork connections.
INSTALL ELECTRICAL WIRING
5. Run 120 VAC housing wiring to installation location.
Use a UL approved connector to secure house wiring
to wiring plate. Connect wires as shown in wiring
diagrams.
MODEL QTRE080R
Page 3