ELECTRICAL CONNECTIONS - WIRING DIAGRAMS
The boiler must be connected to an earthed, single-phase 230V-50 Hz mains supply by means of a three-wire
cable, ensuring that connections to the LINE and NEUTRAL terminals are made correctly.
A bipolar switch must be used with contacts opening to at least 3 mm.
The power lead must only be replaced by another with the following characteristics: "HAR H05 VV-F" 3 X 1.00
mm
2
. (You are strongly advised to use original LAMBORGHINI accessories and spare parts only).
Installation must be made in compliance with safety REGULATIONS IN FORCE.
Make a good earth connection.
Voltage
Frequency
V
230
To gain access to the electrical panel which houses the power supply terminal block and any connection to a
room thermostat, proceed as follows:
G Disconnect the boiler power
supply
G Undo the two grating screws
(fig. 1)
G Undo the two jacket fixing
screws (fig. 2)
G Raise the jacket and then pull it
towards you (fig. 3)
G To access electrical and
electronic parts loosen screws A
and pull the entire panel
outwards
(fig.
downwards and undo the
screws B on the cover C
fig.3