CHARACTERISTICS OF OUTPUT RELAYS
The modules use two guided contacts safety relays (pin 5-6 and 7-8 of CJ6 on
MJB1 and MJB2), (pin 5-6, 7-8 and 9-10 of CJ6 on MJB3 and MJB4), for the output
circuit.
These relays are specified by the manufacturer for voltages and currents greater
than what is indicated in the technical data; nevertheless to guarantee correct
insulation and avoid damage or premature aging, protect each output line with a
3.15 A delayed fuse and verify that the features of the load conform to the
indications on the following table.
Number of contacts
Relay category (according to EN60947-5-1)
Max commutable voltage
Min commutable voltage
Max commutable current
Min commutable current
Number of commutations (life)
FEEDBACK CONNECTION ACTIVE
PFHd
SFF
MTTFd
8,16E-09
99,5%
71,02
6,78E-10
99,5%
851,50
4,35E-11
99,2%
13442,07
1,52E-09
99,5%
378,64
1,28E-10
99,4%
4523,66
9,14E-12
99,0%
67522,13
300s (one commutation every 5 minutes)
t
:
cycle1
3600s (one commutation every hour)
t
:
cycle2
one commutation every day
t
:
cycle3
(PFHd according to IEC61508, MTTFd and DCavg according to ISO13849-1)
16
* 1N.C. = DO NOT USE AS A SAFETY CONTACT
SAFETY DATA
DCavg
99,0%
tcycle1
AC15
98,9%
tcycle2
(6A)
97,6%
tcycle3
99,0%
tcycle1
AC15
98,5%
tcycle2
(2A)
91,9%
tcycle3
MJB1/MJB2
2 N.A.
AC15 / DC13
250Vac, 24Vdc
10Vac/10Vdc
2A
10mA@24Vdc
> 50 x 10
(el) / > 40 x 10
3
FEEDBACK CONNECTION MISSING
PFHd
SFF
MTTFd
4,60E-07
0,50
71,01738
4,43E-09
0,52
851,5035
9,73E-11
0,69
13442,07
1,86E-08
0,51
378,6359
3,62E-10
0,58
4523,66
1,74E-11
0,87
67522,13
MJB3/MJB4
2N.A. - 1N.C.*
(mech)
6
DCavg
0
tcycle1
AC15
0
tcycle2
(6A)
0
tcycle3
0
tcycle1
AC15
0
tcycle2
(2A)
0
tcycle3
8540705 • 18/12/2012 • Rev.6