PASSIVE INFRARED 7709
The 7709 sensor is a detector with passive infrared equipped with a double
pyroelectric element sensor.
Positioning the sensor in a corner it can be protect an area of 10 x 10 meter.
Position the sensor in the area to be protected and the sensor fiel, take into
consideration that infrared sensors are more sensible to the transversal
movement than to the frontal one.
In order to avoid false alarming, do not install in:
!
Areas of intense heat.
!
Strong air current is directed on the sensor.
!
Where there may be vibrations of the wall.
!
Unsteady objects.
! Animals.
INSTALLATON
To install it correctly we suggest to follow the indiations here below, after
establishing the fixing point:
A
Fix the
moulding box
"A" to the wall.
Insert the spherical
side of the detail
"B" in the
appropriate
spherical seat on
the moulding box
"A".
Fit the detail (B) to
the 4 holes on the
sensor bottom until
completely inserted.
B
Now the sensor can
rotate in all
directions.
Adjust the sensor taking into considration the area to be protect and make
some functioning test.
Long ray
2m
Medium ray
Short ray
FUNCTIONING
In order to avoid a fast battery discharge, the sensor inhibits itself for 4 seconds
after an alarm signal.
The sensor will start working normally when the alarm cause has finished;
however not before than 4 minutes.
PROGRAMMING
To couple the sensor with the unit, follow indications reported below
!
Open the sensor cover by pressing the upper and bottom side.
!
Connect the battery to the corresponding connector.
!
Plan the alarm unit for self-learning.
!
Insert the "TX test" jumper in the corresponding pin.
!
Optical and acoustic signals depend on the alarm it has been self-learned.
!
Remove the jumper inserted in "TX test" correponding pin.
!
Close the sensor cover.
JUMPER POSITIONING AND FUNCTIONING TEST
It is possible to verify sensor perfect working order at the end of installation and
programmation stage.
Depending on the test, insert jumper like described below.
WALK TEST
Set the jumper to "WALK TEST" modality; the LED lights at
each movement detected from the sensor and the RF
Set the jumper to "TX TEST" modality in order to have the
TX TEST
TX transmission test. This configuration allows the sensor to
transmit continuously the alarm signal.
Set the jumper in the normal "WORKING MODALITY".
NORMAL
When the sensor detects the movement sends the signal to
WORKING
10m
:
transmission is inhibited.
the unit.