Troubleshooting Guide - Remington REM-40-GFA-O Manual Del Usuario E Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. It will begin
with the letter "G" followed by 9 digits. For Example: G123456789. Have your Serial Number ready
before calling customer service at 866-676-1989.
Problem
Fan does not turn when
electricity is connected.
Heater will not fire (ignite).
Heater stops running
by itself.
© 2017, Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE
BURNING, CONNECTED TO A POWER SOURCE, OR

Troubleshooting Guide

Possible Cause(s)
1. No electric power to heater.
2. Blades of fan in contact with
heater housing.
3. Fan blades bent.
4. Fan motor defective.
1. No spark at module.
2. Incorrect spark gap.
3. Corroded electrode.
1. Temperature inside heater is too
high, causing thermal switch to
shut down operation.
2. Damaged control valve.
3. Dust or Debris accumulated
in heater.
WHILE CONNECTED TO A FUEL SOURCE
1. Check current at outlet. If voltage
is correct, inspect extension and
power cords for cuts, frays or
breaks
2. Check housing for damage. Be
sure there are no dents in the
housing obstructing the fan.
3. Straighten all fan blades.
4. Replace motor assembly.
1. Inspect module wire. Re-attach
or tighten if loose. Inspect spark
module and replace if necessary.
Inspect all other electrical
components.
2. Set plug gap to 0.16" (4 mm).
3. Replace spark plug
(multi-bracket assembly).
1. If the heater input or output is
restricted, the inside temperature
can become too hot. Keep the
areas in front and behind heater
clear of obstructions.
2. Replace control valve.
3. Clean inside of heater.
Propane Forced Air Heater User's Manual
Solution

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rem-60v-gfa-oRem-125v-gfa-oRem-150v-gfa-o

Tabla de contenido