Lighting Instructions - Remington REM-80V-LPC-O Manual Del Usuario E Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EXTREMELY HOT during operation. Do Not touch any metal components while in
WARNING
operation. Keep gasoline and any other flammable liquids away from the heater.

Lighting Instructions:

REM-80V-LPC-O
1. STOP! Read all of the safety information
provided with this heater.
2. Turn valve on propane cylinder
COUNTERCLOCKWISE until fully open.
3. Press in control knob and turn
COUNTERCLOCKWISE to LOW/IGN
position.
4. If burner does not ignite, turn control knob
to OFF position and repeat the ignition
procedure.
5. Keep control knob pressed in for
approximately 30 seconds before releasing.
6. If the flame goes out, wait 5 minutes and
repeat the ignition and lighting steps.
7. After heater ignites, turn the control knob to
desired heat setting.
Relighting Instructions
1. Rotate valve on cylinder CLOCKWISE to close
it and wait 5 minutes.
2. Relight following the Lighting Instructions,
steps 1-7.
Shut Down Instructions
1. Turn control knob to the OFF position.
2. Rotate valve cylinder CLOCKWISE to close it.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
OPERATION (CONT.)
REM-200V-LPC-O
1. STOP! Read all of the safety information
2. Turn valve on propane cylinder
3. Set control valve to LIGHT/LOW position,
4. Depress the red button on the safety valve,
5. When the burner lights, continue to keep the
6. If burner goes out, wait 5 minutes and repeat
7. When burner lights, you can now adjust the
NOTE: When adjusting heat setting, the control
valve only needs to slightly slide up to achieve
HIGH setting.
Relighting Instructions
1. Rotate valve on cylinder CLOCKWISE to close
2. Relight following the Lighting Instructions,
Shut Down Instructions
1. Rotate valve cylinder CLOCKWISE to close it.
9
provided with this heater.
COUNTERCLOCKWISE until fully open.
then wait 15 seconds before step 4.
admitting gas to the burner. While pressing
the safety valve, push and release the
ignition button until the burner lights.
red safety valve depressed for 30 seconds
then release.
lighting procedure.
heat setting to HIGH by sliding the control
valve up to the HIGH setting.
it and wait 5 minutes.
steps 1-7.
Convection Heater User's Manual

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rem-200v-lpc-o

Tabla de contenido