WARNING
The products described in this manual are kero-
sene direct-fired, forced air heaters. Kerosene
forced air heaters are primarily intended for use
for temporary heating of buildings under con-
struction, alteration or repair. Direct-fired means
that all of the combustion products of the heater
enter the heated space. This appliance is rated
at 98% combustion efficiency, but does produce
small amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation
in accordance with the instructions in this manual
can result in death.
DANGER
People with breathing problems should consult a
physician before using this heater.
Early signs of carbon monoxide poisoning re-
semble the flu. Symptoms of improper ventilation
/ carbon monoxide poisoning are:
Headache • Dizziness • Nausea • Dry Mouth
Sore Throat • Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more affected by carbon monoxide
than others. These include: pregnant women,
those with heart or lung problems, anemia or
those under the influence of alcohol or at high
altitudes.
Not For Indoor Use. Indoor use permitted only
for the temporary heating of buildings under
construction, alteration or repair!
Provide at least a three square foot (2,800 sq
cm) opening of outside air for every 100,000
Btu/Hr (29 kW) heater rating. Refer to "Ventila-
tion" on page 6 for further instructions.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
SAFETY INFORMATION (CONT.)
RISK OF INDOOR
AIR POLLUTION!
CARBON MON-
OXIDE POISON-
ING MAY LEAD TO
DEATH!
WARNING
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
WARNING
NEVER use fuels such as gasoline, benzene, paint
thinners or other oil compounds in this heater.
NEVER refill the heater's fuel tank while the heater
is operating or still hot. This heater is EXTREMELY
HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
150T-SDR
Top
4 ft. (125 cm)
Sides
4 ft. (125 cm)
Front
8 ft. (250 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it
is plugged in, it can start at anytime in accordance
with the thermostat setting.
WARNING
NOT TOUCH. KEEP CHILDREN, ANIMALS,
CLOTHING AND COMBUSTIBLES AWAY
FROM HEATER.
3
Silent Drive Forced Air Heater User's Manual
RISK OF ELECTRIC
SHOCK!
RISK OF BURNS,
FIRE AND EXPLO-
SION!
220T-SDR
4 ft. (125 cm)
4 ft. (125 cm)
8 ft. (250 cm)
CAUTION! HOT
WHILE IN OP-
ERATION. DO