The values or options in the screen displays shown must be entered before start-up.
TABLE 1.
SAFETY
SETPOINTS
LO SUCT PRESS
SETPOINT #1
SETPOINT #2
HI DISCHARGE PRESS
SETPOINT #1
SETPOINT #2
HI DISCHARGE #2 PRESS
SETPOINT #1
SETPOINT #2
LO SUCTION TEMP
HI DISCHARGE TEMP #1
LO CRANKCASE OIL TEMP-
START
LO CRANKCASE OIL TEMP-
RUN
HI DISCHARGE TEMP #2
LO CONTROL TEMP
HI CONTROL TEMP
LO OIL PRESSURE
HI START FLTR DIFF PR
HI OIL RUN FILTER DIFF PR
NOTES:
(1)
Set only if Comp Control Via Process Temperature is selected.
VANTAGE RECIP MICROCONTROLLER
MANUAL DE OPERACIONES
SYSTEM SETPOINTS ALARMS & TRIPS WORKSHEET
SYSTEM VALUES
ALARM TRIP RESET
(1)
(1)
VALUE LIMITS
ALARM
TRIP
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
30"/300
-99/300
-99/300
-99/300
-30/325
-30/325
-30/325
60/200
60/200
60/200
60/200
-30/325
-30/325
-30/325
-99/210
-99/210
-99/210
-99/210
- - -
15/300
15/300
30"/40
30"/40
30"/40
30"/40
- 37 -
DEFAULT VALUES
RESET
ALARM
TRIP
3"
4"
1"
2"
210
220
220
230
210
220
220
230
-45
-50
205
210
60/200
75
70
60/200
105
100
205
210
-50
-55
- - -
100
- - -
15/300
25
20
30"/40
40
40
30"/40
12
15
NUEVA EDICION
RESET
2"
1"
205
215
205
215
-45
200
80
110
200
-45
95
27
25
10
04/03

Publicidad