Descargar Imprimir esta página

Cree C-Lite Instrucciones De Instalación página 2

Led de panel plano con respaldo de emergencia

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
C-LITE LED Flat Panel With
Emergency Back-up
NOTE: Luminaire equipped with universal volt driver 120-277V. Connecting luminaire to voltage outside the range of 120-277V may result
in luminaire damage and/or improper luminaire operation. The emergency driver must be fed from the same branch as the AC Driver.
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect the black luminaire lead from the emergency driver to the voltage supply hot lead.
2. Connect the black luminaire lead from the LED driver to the supply switched hot lead.
3. Connect the white luminaire lead from the emergency driver to the neutral supply hot lead.
4. Connect the green/yellow luminaire ground lead to the supply ground lead.
5. Connect the violet (+) test switch lead from the emergency driver to the violet lead from the test switch.
6. Connect the brown (-) test switch lead from the emergency driver to the brown lead from the test switch.
Tuck all wires carefully into wiring chamber ensuring that no wires are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect the black luminaire lead from the emergency driver to the L1 voltage supply hot lead.
2. Connect the black luminaire lead from the LED driver to the L1 supply switched hot lead.
3. Connect the white luminaire lead from the emergency driver to the L2 supply hot lead.
4. Connect the green/yellow luminaire ground lead to the supply ground lead.
5. Connect the violet (+) test switch lead from the emergency driver to the violet lead from the test switch.
6. Connect the brown (-) test switch lead from the emergency driver to the brown lead from the test switch.
Tuck all wires carefully into wiring chamber ensuring that no wires are pinched.
DIMMING
1. If 0-10V dimming is used, connect supply positive dimming lead to luminaire positive dimming
[0-10V (DIM +)] violet terminal on terminal block in driver wiring chamber.
2. If 0-10V dimming is used, connect supply negative dimming lead to luminaire negative dimming
[0-10V (DIM -)] grey terminal on terminal block in driver wiring chamber.
N
L
WALL
SWITCH
FIXTURE WIRING
WHITE
(120-277V)
BLACK
WHITE/BLACK
GROUND
TEST +
(VIOLET)
TEST -
(BROWN)
WHITE
DIM (+)
VIOLET
DIM (-)
GREY
BLACK
http://lighting.cree.com/warranty
Document:
LPN00553X0001A0
Created By:
TMT
THESE CONNECTIONS ARE MADE
AT FACTORY. NO SPLICES
REQUIRED BY CONTRACTOR
TO LED LEADS
LED + (GREY)
LED - (WHITE)
DRIVER - (BLACK)
DRIVER +
(RED)
RED (+)
LED DRIVER
BLACK (-)
|
866.924.3645
Date
98-1-2019

Publicidad

loading